how to identify novastar device’s state based on the LED indicator

NovaStar LED Indicator States Explained: How to Read Device Signals

How to Identify Novastar Status Indicators

This guide provides step-by-step instructions on interpreting status indicators for Nova M3 system components. Understanding these indicators is crucial for troubleshooting and ensuring proper system operation.

1. How to Interpret Receiving Card Indicators

Each receiving card has two indicators: red (power) and green (status).

🔹 Power Indicator (Red)

StatusMeaning
OnPower supply is normal
OffNo power supply

🔹 Status Indicator (Green)

StatusMeaningAction Required
OnWorking normally, signal comes from master channelNone
Flashing at 1 Hz (once per second)Working normally; signal comes from redundancy channelNone
On for 0.5s, then quick flashing for 0.5sWorking normally; signal comes from redundancy channelNone
Flashing at 7 Hz (once every 0.15s)Authorization expiredCheck authorization status
Flashing at 0.2 Hz (once every 5s)Data connection failure (RJ45 Ethernet cable connection failure)Check Ethernet connection
Flashing 3 times, then off for 0.5sWorking in boot mode (firmware update failed)Reboot system or reflash firmware

2. How to Interpret Sending Unit Indicators (MSD300)

Each MSD300 has two indicators: red (power/MCU status) and green (FPGA status).

🔹 Power Indicator (Red)

StatusMeaning
OnPower supply working normally
OffPower supply not working
Flashing (20Hz)Authorization expired (green indicator should be off)

🔹 FPGA Indicator (Green)

StatusMeaning
OnFPGA working normally
Flashing at 2.98 Hz (each 0.3s)FPGA working normally
Quick flashing at 23.8 Hz (each 42ms)Showing the booting image
Slow flashing at 0.37 Hz (each 2.7s)No DVI input; no image output to the screen
OffFPGA not working or authorization expired

3. How to Interpret Sending Unit Indicators (MCTRL500)

Each MCTRL500 has three indicators: red (power/MCU), green (FPGA), and DVI.

🔹 Power Indicator (Red)

StatusMeaning
OnPower supply working normally
OffNo power supply
Flashing (20Hz)Authorization expired

🔹 FPGA Indicator (Green)

StatusMeaning
OnFPGA working normally
Flashing at 2.98 Hz (each 0.3s)FPGA working normally
OffFPGA not working or authorization expired

🔹 DVI Indicator

StatusMeaning
OnDVI input is good
OffNo DVI input

4. How to Interpret Monitor Card MON300 Indicators

Each monitor card has two indicators: power and FPGA.

🔹 Power Indicator

StatusMeaning
OnPower supply is normal
OffNo power supply

🔹 FPGA Indicator

StatusMeaning
OnFPGA working normally
Flashing at 0.74 Hz (each 1.3s)The FPGA is not working normally

5. How to Interpret Function Card MFN300 Indicators

Each function card has two indicators: power and FPGA.

🔹 Power Indicator

StatusMeaning
OnPower supply is normal
OffNo power supply

🔹 FPGA Indicator

StatusMeaning
OnFunction card working normally; can be accessed through RJ45 or serial port
Flashing at 0.74 Hz (each 1.3s)Function card not working normally
Flashing at 0.37 Hz (each 2.7s)Function card working normally; can only be accessed through serial port (RJ45 port connected or connection not good)
Flashing at 2.98 Hz (each 0.34s)Firmware loading failed

6. How to Interpret EO Convertor CVT310/320 Indicators

Each EO convertor has four indicators: Power, Fiber Connection, Ethernet Connection, and Data Transmission.

🔹 Power Indicator

StatusMeaning
OnPower supply is normal
OffNo power supply

🔹 Fiber Connection Indicator

StatusMeaning
OnFiber connection is good
OffFiber not connected

🔹 Ethernet Connection Indicator

StatusMeaning
OnEthernet cable connection is good
OffEthernet cable not connected

🔹 Data Transmission Indicator

StatusMeaning
Flashing at 2 Hz (each 0.5s)Data transmission between two EO convertors is normal
OffNo data transmitted

Troubleshooting Checklist

  1. Check power indicators first - Always verify power supply before troubleshooting other indicators
  2. Check physical connections - Verify all cables (RJ45, DVI, fiber) are properly connected
  3. Check authorization status - Authorization expiration often causes green indicator issues
  4. Firmware issues - If boot mode is active (flashing 3 times), firmware may need reinstallation
  5. Redundancy channels - If green indicator flashes at 1 Hz, system is using redundancy channel

💡 Pro Tip: When troubleshooting, start with the most basic indicators (power) before moving to more complex status indicators.

Status indicators tell you whether a panel is healthy. They cannot tell you whether it is the right panel for the room. Where operators view the wall from two to four metres, as in a control room or broadcast gallery, pixel pitch matters more than brightness. Our fine pitch LED display range covers the sub-2mm panels used in those close-viewing installations.

This knowledge base article provides a comprehensive guide to interpreting Nova M3 status indicators. For more detailed information, refer to the official Nova M3 documentation on www.novastar.tech.